Indramat E251 Motor Overtemperature Warning

18 December, 2023 | Indramat, E251, Motor, Overtemperature, Warning, Meaning

Indramat Servo Motor with E251 error title

In industrial automation, understanding the nuances of equipment like the Indramat E251 Motor is crucial. This motor, a staple in Rexroth automation servo motors, is pivotal in maintaining operational efficiency in various facilities.


Decoding the E251 Motor Warning:

The E251 warning in an Indramat motor is like a friendly tap on the shoulder. It means, "Hey, I'm getting a bit too hot here!" Specifically, it activates when the motor's temperature crosses 145°C. This isn't just a random number; it's carefully set to prevent damage. Unlike a shutdown code that stops things dead, this warning keeps the motor running, allowing us to fix the issue. It's smart, really – a warning before things turn serious. It is a gentle reminder to check and cool down your motor.


Causes of E251 Motor Overheating:

  1. Overloading the Motor: Pushing the Indramat motor beyond capacity is a common trigger for the E251 warning.
  2. Installation Errors: The motor might become too hot if it isn't set up properly. For optimal performance, proper configuration is essential.
  3. Accumulation OF Dirt: Motors with surface cooling dissipate heat through their housing, requiring clean surfaces for optimal heat release. In the case of motors using blower units, maintaining clean vents is crucial for efficient heat dissipation.
  4. Thermo Sensor Malfunction: A faulty thermo sensor can incorrectly gauge the motor temperature, leading to overheating. This can happen due to sensor damage, improper installation, or electrical issues.
  5. Incorrect Parameter Settings: Setting up the motor with the wrong parameters can lead to overheating. It's like giving it the wrong instructions.

These factors can, independently or in combination, lead to an E251 warning. It's about finding and fixing these issues to keep the motor running smoothly.


Troubleshooting and Resolving E251 Warnings:

Addressing E251 Motor Warnings: A Step-by-Step Guide

Step 1: Identify the Warning: First, confirm the E251 warning on the H1 display. It specifically indicates motor overheating.

Step 2: Cease Operation: Temporarily halt the motor's operation to prevent further stress and potential damage.

Step 3: Check Environmental Factors: Ensure that the surrounding temperature is conducive for operation. The acceptable temperature range is 0 to +45 degrees centigrade.

Step 4: Inspect for Physical Blockages: Look for any obstructions, like dirt or debris, that could impair motor cooling.

Step 5: Evaluate Motor Conditions: Examine the motor for signs of wear or damage that could cause overheating.

Step 6: Consult for Thermo Sensor Malfunction: If you suspect a malfunction in the thermo sensor, consult an Indramat product repair shop for specialized assistance.

Step 6: Reset and Monitor: After addressing these aspects, reset the system and closely monitor the motor's performance.


Tips for Checking Motor Ratings and Conditions

  • Review Motor Specifications: Ensure the motor's operating parameters align with its specifications.
  • Assess Motor Load: Verify that the motor is not overloaded beyond its rated capacity.
  • Inspect for Cleanliness: Dirt accumulation can cause overheating, so keep the motor clean.
  • Check Ventilation: Proper airflow is essential for cooling; ensure clear ventilation paths.

Following these steps and tips, you can effectively troubleshoot and resolve E251 warnings, ensuring your Indramat motor operates safely and efficiently.


Still Facing the Warning Problem? Consult Wake Industrial for Expert Solutions

Wake Industrial stands out in industrial automation, especially in handling Rexroth Indramat products. We specialize in various Indramat products, including MSK series motors, MHD series motors, and MDD series motors, catering to diverse industrial needs. Wake Industrial is a reliable partner if your Indramat motor requires repair or if you're looking to purchase or sell Indramat components.