Part Number:

EEA-PCB-405-A-20

Manufacturer: Vickers
Series: EEA-PAM-5**-A-30 Series

Current response time:

5 Minutes

55 Seconds

  • Rated 4.5 (24 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The Vickers EEA-PCB-405-A-20 module, part of the EEA-PAM-5**-A-30 Series, has a rated frequency of 50/60 Hz. It maintains an EMC level of Class A and possesses a power loss of 25 watts and a current capacity of 80 amperes. With a maximum temperature tolerance of 45°C, the conductor cross-section measures 25 mm².

Part Number:

EEA-PCB-405-A-20

Manufacturer: Vickers
Series: EEA-PAM-5**-A-30 Series

Current response time:

4 Minutes

13 Seconds

  • Rated 4.5 (24 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The Vickers EEA-PCB-405-A-20 module, part of the EEA-PAM-5**-A-30 Series, has a rated frequency of 50/60 Hz. It maintains an EMC level of Class A and possesses a power loss of 25 watts and a current capacity of 80 amperes. With a maximum temperature tolerance of 45°C, the conductor cross-section measures 25 mm².

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The EEA-PCB-405-A-20 from the Series Vickers EEA-PAM-5-A-30 is a very efficient and reliable electronic component that can be used for power controlling and protecting industrial applications.

It currently draws a current of 80A and has a power loss of 25 W; this makes this unit very efficient in managing energy while at the same time not generating much heat. This device is intended to be powered at a voltage of 480V AC; thus it is suitable for use in numerous industrial power systems. EMC level is Class A, meaning this device complies with the electromagnetic emissions limits produced by information technology equipment. The cross-sectional area of the conductor is 25mm², which guarantees the stable work of the cable with a reliable design. The unit measures 80mm by 398mm by 200mm and weighs 6kg, making it a suitable component for most systems. It works at a frequency band of 50 / 60 Hz which is suitable for most power systems in the world. More details include a leakage current of 35mA making it safe to use without the risk of electric shock. The maximum working temperature is 45°C and therefore suitable for use in conditions of moderate temperatures only.

The EEA-PCB-405-A-20 has an overload capability of 120% of the rated current for 2 minutes to protect the circuit during short periods of high current. It can be installed in areas up to 2000 meters above sea level and still operate to the optimum. It has protection from overvoltage, short circuit, and thermal to secure the safe and stable working of the unit. For cooling, the device employs natural convection, while the optional fan-assisted cooling can be used. The unit can be mounted either in the horizontal or vertical position making it easier to position the unit. Wake Industrial offers a one-year guarantee on this product.

EEA-PCB-405-A-20 Technical Specifications

Current: 80 A
Voltage: 480 V AC
Overload Capacity: 120% of rated current for up to 2 minutes
Operating Altitude: Up to 2000 meters above sea level
Protection Features: Overvoltage, short-circuit, and thermal protection
Cooling Method: Natural convection
Mounting Orientation: Horizontal/Vertical
Power Loss: 25 W
Emc Level: Class A
Cross-section Of Conductor: 25 mm²
Dimensions: 80 x 398 x 200 mm
Weight: 6 kg
Frequency: 50/60 Hz
Rated Leakage Current: 35 mA
Maximum Temperature: 45°C

Frequently Asked Questions about EEA-PCB-405-A-20


Q: What is the current and power loss for the EEA-PCB-405-A-20?

A: The EEA-PCB-405-A-20 draws a current of 80A and has a power loss of 25W, making it highly efficient for energy management.

Q: What is the voltage requirement for the EEA-PCB-405-A-20?

A: The device operates at a voltage of 480V AC, making it suitable for most industrial power systems.

Q: What is the maximum operating temperature for the EEA-PCB-405-A-20?

A: The EEA-PCB-405-A-20 has a maximum operating temperature of 45°C, making it suitable for moderate-temperature environments.

Q: What protection features does the EEA-PCB-405-A-20 offer?

A: The EEA-PCB-405-A-20 is equipped with protection against overvoltage, short circuit, and thermal overload, ensuring stable and safe operation.

Q: What are the cooling options for the EEA-PCB-405-A-20?

A: The device uses natural convection cooling, with an optional fan-assisted cooling for environments with higher cooling requirements.

Internal Product Review

  • ‘‘The Vickers EEA-PCB-405-A-20 from the EEA-PAM-5-A-30 Series is a highly efficient electronic component designed for reliable power control and protection in industrial systems. With its low power loss, robust overload protection, and versatile cooling options, this unit is ideal for a wide range of industrial applications requiring high efficiency and safety.’’