Wake Industrial LLC is not an authorized distributor of this product.

AKT-AT-410-000

  • Rated 4.7 (10 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options

The AKT-AT-410-000 is manufactured by Kollmorgen as part of their Advanced Kollmorgen Terminal series. It contains a Signal Voltage of 10 VDC and a Current Consumption Standard-bus of 20 mA. The AKT-AT-410-000 also has No address setting - configuration via Bus Coupler or controller and an Electrical Isolation of 500 V rms.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The AKT-AT-410-000 is a four-channel analog input module manufactured by Kollmorgen Automation. The AKT-AT-410-000 generates signals within the voltage range of 0 to 10 Volts. The voltage is supplied to the AKT-AT-410-000 process level with a resolution of about 12 bits while the voltage is electrically isolated during transmission. The AKT-AT-410-000 bus terminal features four outputs with double wire versions, featuring common ground potential. The AKT-AT-410-000 comes with LEDs that indicate the data exchange with the bus coupler, ensuring easy monitoring of the operation status. The unit comes with IP 20 protection class while the installation position is variable. The current consumption from the standard bus is typically 100 mA

The AKT-AT-410-000 features a conversion timing of 2 milliseconds while the electrical isolation is 500 Volts. The power supply for the electronics is through a Standard-Bus, while the current consumption from the standard-Bus is typically 100 mA. To ensure proper functioning of the unit, the manufacturer recommends that it is stored and operated within the ambient conditions. The ambient operation temperature is 0 degrees Celsius to 55 degrees Celsius while the permissible ambient temperature during storage is rated at -25 degrees Celsius to 85 degrees Celsius. The permissible relative humidity is 95% none condensing. The I/O terminal is single-ended and features a common ground potential.

Before starting the components installation, ensure that the bus terminal system has been brought into a safe, powered down state. The manufacturer recommends the use of KAS Integrated Development Environment over manual configuration. Use the power contact labeled as PE as the Protective Earth. For electromagnetic compatibility, the PE contacts are coupled to the mounting rail. Therefore, for insulation testing, it is recommended that the PE supply line is disconnected at the bus coupler. Further, the PE power contact must not be used for the other potentials.

  • AKTAT410000
  • AKT AT 410 000
  • AKTAT-410-000

AKT-AT-410-000 Technical Specifications

:
Configuration: No address setting - configuration via Bus Coupler or controller
Current Consumption Standard-bus: 20 mA
Electrical Isolation: 500 V rms
Signal Voltage: 10 VDC
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo