Wake Industrial LLC is not an authorized distributor of this product.

VT-HACD-1-EFF00237

  • Rated 4.5 (12 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • MPN: R978050204

Current response time:

5 Minutes 6 Seconds

The VT-HACD-1-EFF00237 digital control unit is manufactured by Bosch Rexroth Indramat. This unit's components are factory assigned and deliver quality performance.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The Bosch VT-HACD-1-EFF00237 is a command value and control card. You can use it as a command value card to generate, link and standardize signals. You can use it as a control card for control loops with PIDT1 controller and state feedback. The card is based on a microcontroller that controls all the processes, makes adjustments, establishes links and realizes the closed control loops. Data for configuration, command values and parameters are stored on non-volatile FLASH memory. The I/O interface on the VT-HACD-1-EFF00237 card is a 64-pole male connector. The RS-232 serial interface has a D-sub socket. The card is available in a Euro-card format that measures 100 x 160 millimeters. For the local bus, the distance to the farthest device is 280 meters. The height of the front plate is 128.4 millimeters and the width is 5.08 millimeters.

Scan time for the VT-HACD-1-EFF00237 card is two milliseconds. Line driver for the SSI transducer is RS-485 and the signal level for the incremental sensor is 5 to 24 Volts DC. The operating voltage is 24 volts DC. The operating voltage range is 21 to 30 Volts DC. Current consumption of the VT-HACD-1-EFF00237 during standby is 250 milliamps. The safety fuse on the card has 4 Amps rating and it is a time-lag fuse. A display and keypad on the front panel can be used by operators for diagnostic purposes, and to display and change card parameters. A PC-based software can also be used for card configuration. The card supports several error monitoring capabilities. Distance between the VT-HACD-1-EFF00237 and any nearby radar systems and radios should be at least 1 meter. Power cables should not be laid in the immediate vicinity of the VT-HACD-1-EFF00237 card.

  • vt-hacd-1-eff00237
  • VT HACD 1 EFF00237

VT-HACD-1-EFF00237 Technical Specifications

Bus Connection: Factory Assigned
Component Series: Factory Assigned
Current Consumption: Factory Assigned
Operating Voltage: Factory Assigned
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo