Part Number:

PSI63C0.168-L2

Manufacturer: Bosch Rexroth Indramat
Series: PSI Frequency Inverter Series

Current response time:

4 Minutes

52 Seconds

  • Rated 4.6 (28 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The PSI63C0.168-L2 is a compact frequency inverter with dimensions of 80 x 398 x 200 mm and a power loss of 25 W. Produced by Bosch Rexroth Indramat, it belongs to the PSI Frequency Inverter Series and features a rated leakage current of 35 mA. This inverter operates at a frequency of 50/60 Hz.

Part Number:

PSI63C0.168-L2

Manufacturer: Bosch Rexroth Indramat
Series: PSI Frequency Inverter Series

Current response time:

6 Minutes

45 Seconds

  • Rated 4.6 (28 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The PSI63C0.168-L2 is a compact frequency inverter with dimensions of 80 x 398 x 200 mm and a power loss of 25 W. Produced by Bosch Rexroth Indramat, it belongs to the PSI Frequency Inverter Series and features a rated leakage current of 35 mA. This inverter operates at a frequency of 50/60 Hz.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The Bosch Rexroth Indramat PSI63C0.168-L2 of the PSI Frequency Inverter Series is a high-end device developed to meet industrial specifications with efficiency.

This model comes with the capability of handling 80A current and has a relatively low power consumption of 25W. It is EMC class A compliant thus having low interference with other electronic devices, especially amid other electromagnetic equipment. The inverter has a 25 mm² conductor cross-section, with a small size of 80 x 398 x 200 mm and a weight of 6 kg, which allows it to be installed in different configurations. It works with a voltage of 50/60 Hz, has a leakage current of 35 mA, and is capable of working in temperatures of up to 45 degrees Celsius. One of the most important characteristics of this inverter is the cooling system by forced airflow, which is crucial for maintaining good working conditions and avoiding overloading during long periods of usage. The inverter can therefore be safely stored within a low temperature of -25°C and a high of 70°C allowing for the usage in extreme conditions. The weld timer’s CPU is powered by a 30Volts DC which is compliant with EN 61131-2 standard to enhance the reliability of the device.

For securing safety and to meet the requirements about protective grounding, DIN VDE 0160 is prescribed for the inverter used in industrial setups. It also provides a wide range of connectivity aspects due to dedicated interface slots that enable parallel, serial, or Fieldbus connection for easy integration into other systems. Adherence to the IEC 61131-2 standard also serves to reaffirm the inverter’s readiness for programmable controllers, implementation of which is assured for the industrial environment. All these characteristics therefore make the PSI63C0.168-L2 a flexible and reliable solution for many Industrial applications.

PSI63C0.168-L2 Technical Specifications

Current: 80 A
Cooling Method: Forced-Air Cooling
Storage Temperature Range: -25°C to 70°C
Voltage Rating: 30VDC
Protective Grounding Requirement: DIN VDE 0160
Interface Slots: Available
Compliance: EN 61131-2
Power Loss: 25 W
Emc Level: Class A
Cross-section Of Conductor: 25 mm²
Dimensions: 80 x 398 x 200 mm
Weight: 6 kg
Frequency: 50/60 Hz
Rated Leakage Current: 35 mA
Maximum Temperature: 45°C

Frequently Asked Questions about PSI63C0.168-L2


Q: What makes the PSI63C0.168-L2 suitable for various industrial applications?

A: The PSI63C0.168-L2 is versatile with its compact size, efficient power management, and robust cooling system, making it suitable for diverse installation configurations and demanding industrial tasks.

Q: How does the forced air cooling system benefit the PSI63C0.168-L2?

A: The forced air cooling system in the PSI63C0.168-L2 is crucial for maintaining optimal operating temperatures, thereby preventing overloading and prolonging the device's operational lifespan, especially during extended use periods.

Q: What connectivity options does the PSI63C0.168-L2 offer?

A: This inverter features dedicated interface slots for parallel, serial, or Fieldbus connections, allowing for seamless integration into various industrial systems and facilitating easy management and data transfer.

Q: How does the PSI63C0.168-L2 handle extreme temperatures?

A: The PSI63C0.168-L2 is designed to operate within a broad temperature range, from as low as -25°C to as high as 70°C, accommodating extreme environmental conditions while maintaining performance.

Q: What standards does the PSI63C0.168-L2 comply with to ensure safety and reliability?

A: The PSI63C0.168-L2 adheres to EN 61131-2 and DIN VDE 0160 standards, ensuring high reliability and safety for protective grounding, crucial for meeting industrial safety requirements, and enhancing device efficacy.

Internal Product Review

  • ‘‘The Bosch Rexroth Indramat PSI63C0.168-L2 stands out in the industrial sector with its EMC Class A compliance and robust forced air cooling system, ensuring reliable operation and integration into various industrial environments without the risk of electromagnetic interference.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo