KDA 2.1-150-300-AP0-U1/115
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911228560
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
In-Stock, Ships Today
The KDA 2.1-150-300-AP0-U1/115 main spindle drive by Bosch Rexroth comprises a programming module. This spindle drive features a DC bus voltage. It must be grounded before its operation.
To contact sales for pricing and lead time:
Payment Methods




Shipping Methods




Our Credentials




Product Description:
The KDA 2.1-150-300-AP0-U1/115 main spindle drive by Bosch Rexroth is designed only for industrial use and must be handled and operated as intended. This spindle drive assembly, installation, operation and maintenance should be undertaken only by qualified and trained personnel. The product must undergo a commissioning action before it is operated. This device is equipped with a programming module. The unit portrays standardized electrical connections. It must be connected using only the manufacturer's readymade preassembled cables. This drive comes with its mechanical and electrical connecting accessories packed separately. The product should be free of load when it is being transported. This device is attached to the back panel of a control enclosure. The unit portrays a +/-10 V analog speed value. It uses a heatsink blower with a voltage rating of 115 VAC and a frequency rating of 50/60 Hz for its cooling. This spindle drive is synchronized with the associated motor by using parameters. The product related programming module stores two sets of parameters in its operating software. This device is supposed to be stored in a clean and dry place. The unit must be installed only vertically inside the control cabinet. Its blower associated air duct must be fixed using a very long screwdriver. This spindle drive should not be put into operation in the damaged state. The product installation has to be done in accordance with the regulations specified in the documentation. This device cannot be used for applications that are not approved by the manufacturer. The unit may have a high electrical voltage because of an incorrect connection. It must be installed only after understanding the details given in its documentation.
Frequently Asked Questions about KDA 2.1-150-300-AP0-U1/115:
Q: Does the KDA spindle drive require periodic maintenance?
A: No, the KDA spindle drive does not require periodic maintenance if it is used as intended by the manufacturer.
Q: What is the power bridge of the KDA spindle drive used for?
A: The power bridge of the KDA spindle drive is used to convert the DC bus to a rotating three-phase power supplied to the AC spindle motor.
Q: Is the KDA spindle drive protected against water?
A: No, the KDA spindle drive is not protected against water and it is the user's responsibility to ensure this protection.
Q: Where is the grounding bolt of the KDA spindle drive located?
A: The grounding bolt of the KDA spindle drive is located on its top.
Q: How many pins does the bus terminal strip of the KDA spindle drive have?
A: The bus terminal strip of the KDA spindle drive has 14 pins.