Part Number:

KCU02.2N-ET-ET-025-NN-N-NN-MW

Manufacturer: Bosch Rexroth Indramat
Series: KCU Servo Drive Series
  • Rated 4.5 (17 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The KCU02.2N-ET-ET-025-NN-N-NN-MW Bosch Rexroth drive connection box cannot be operated on its own. This connection box has live connecting points during its operation. It is positioned near the supply unit in a control system.

Part Number:

KCU02.2N-ET-ET-025-NN-N-NN-MW

Manufacturer: Bosch Rexroth Indramat
Series: KCU Servo Drive Series
  • Rated 4.5 (17 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The KCU02.2N-ET-ET-025-NN-N-NN-MW Bosch Rexroth drive connection box cannot be operated on its own. This connection box has live connecting points during its operation. It is positioned near the supply unit in a control system.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The KCU02.2N-ET-ET-025-NN-N-NN-MW Bosch Rexroth drive connection box is compatible with only the manufacturer's range of offerings. This connection box can be operated only after mounting a touch guard. The product supplies the KSM and KMS servo drives with 42 V control voltage. This device has a fixed configuration. The unit encompasses LEDs on its front panel for diagnostics purposes. Its type plate is positioned above the UL performance data plate. This connection box is completely backward compatible with its earlier version. The product portrays 2K3 climatic category according to IEC 721 specifications for storage. This device encompasses electrolytic capacitors that tend to deteriorate during its storage period. The unit should be protected against conductive dirt contamination on its surface. It must never be operated at an altitude higher than 4000 m over sea level. This connection box supports only G1 mounting orientation. The product has two fuse outputs with 30 A current rating on its front panel. This device can be connected to a neighboring device by using the joint bar equipment grounding conductor. The unit must have a connection at all its connecting points for the safe and correct functioning of the drive. This drive connection box must be used with a control cabinet adapter when it is connected to the manufacturer's HMV01 and HCS03 devices. Its hybrid cable must always be connected to the X103.1 connecting point of the first servo drive. The product supports up to 50 plugging cycles for its hybrid cable. This device is not needed when a KMV power supply or a HCS01 converter is used. It is necessary to place the servo drive with the highest power as close as possible to the output of the connection box.

KCU02.2N-ET-ET-025-NN-N-NN-MW Technical Specifications

Family: KCU
Protection Class: IP 20
Series Code: 1
Design Code: 2
Configuration: Fixed
Input Communication Module: Multi-Ethernet
Output Communication Module: Multi-Ethernet
Nominal Current Rating: 25 A
Safety Option Interface: No
Control Panel: No

Frequently Asked Questions about KCU02.2N-ET-ET-025-NN-N-NN-MW


Q: What is the mounting position of the KCU connection box?

A: The KCU connection box can be mounted only in a vertical position.

Q: What is the derating percentage of the KCU connection box when the maximum ambient operating temperature is exceeded?

A: The derating percentage of the KCU connection box when 2% for every degree rise in temperature above the maximum ambient limit.

Q: What is the tightening torque of the screw used with the touch guard of the KCU connection box?

A: The tightening torque of the screw used with the touch guard of the KCU connection box is 2.8 Nm.

Q: What happens when a KCU connection box is used at the 42 V control voltage output?

A: The rated power at the 42 V control voltage output is reduced when a KCU connection box is used.

Q: How is the hybrid cable of the KCU connection box protected against thermal overload?

A: The hybrid cable of the KCU connection box is protected against thermal overload by means of integrated fuses.