The HVE03.2-W030 Power Supply System is manufactured by Rexroth Indramat Bosch. This power supply system has a rated power voltage of 30 and a nominal voltage of 380 to 480V.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The HVE03.2-W030 power supply unit is used for connecting to drive controllers. The second-generation Bosch Rexroth product is compatible with the manufacturer’s HDD and HDS drive controllers. The module is integrated with a power rectifier that helps to rectify the three-phase AC voltage. It belongs to the DIAX04 family group. It can be isolated from the mains by an internal power contactor. The communication between the device and the drive controller is through the control bus voltage. One power supply unit can be connected to multiple drive controllers. The product is backed by a warranty for one year.

The power supply unit has a maximum regenerated energy of 100kW when it is connected to a 3 x 480V mains nominal voltage. This module supports the combination with a GLD DC bus choke to increase the usable DC bus continuous power. It may get damaged if there is an overload. The device features a frequency range of 50Hz to 60Hz +/-2Hz. The unit operates in an ambient temperature range of 5°C to 45°C with rated data. The product slows the application of short-term loads for the acceleration of spindle and feed drives. The connected load of the module helps in determining line cross-sections and mains fuses.

The DC bus of the product can be connected with 10mF additional capacitance. This unit must consider load factors when it is operated outside the specified conditions. There is a loss of heat inside the control cabinet that the module is installed in due to bleeder, power, and basic losses. The device may experience condensation due to the use of a cooling unit. It is not protected against intentional access. The surface of the product tends to become very hot during operation. This power supply unit is shippable to any country across the globe.

  • HVE03.2W030
  • HVE-03.2-W030
  • HVE 03.2 W030
  • HVE3.2-W030

HVE03.2-W030 Technical Specifications

Nominal Voltage: 380 to 480V
Pollution Category: 2
Maximum Regenerated Energy : 100 kW
Frequency Range : 50 - 60 Hz
Frequency Range Tolerance: (+/-2 Hz)
Reverse Polarity Protection: Available
Short Circuit Protection: Available
Operating Temperature Range: (+5 to +55) degree centigrade
Maximum Elevation Height: 1000 MSL
Maximum Allowable Humidity: 95%

Frequently Asked Questions about HVE03.2-W030


Q: What drive controllers are compatible with the HVE03.2-W030 power supply unit?

A: The HVE03.2-W030 is specifically designed to connect with Bosch Rexroth HDD and HDS drive controllers. As a second-generation product, it ensures seamless compatibility with these controllers, allowing for efficient power supply and communication through the control bus voltage.

Q: How does the HVE03.2-W030 handle AC voltage and what family does it belong to?

A: This unit features an integrated power rectifier that efficiently converts three-phase AC voltage for use. It's a part of the DIAX04 family group, known for its robust power supply solutions in industrial settings.

Q: Can the HVE03.2-W030 power supply unit be isolated from the mains?

A: Yes, it is designed with an internal power contactor that allows it to be isolated from the mains. This feature provides added safety and control over the power supply to the connected drive controllers.

Q: What additional components can be used with the HVE03.2-W030 to enhance its performance?

A: The HVE03.2-W030 can be combined with a GLD DC bus choke to increase the usable DC bus continuous power. This addition is particularly useful in scenarios demanding higher power continuity and efficiency.

Q: What are the limitations and heat management considerations for the HVE03.2-W030?

A: The unit can be adversely affected by overloads and experiences heat loss due to bleeder, power, and basic losses inside the control cabinet. Additionally, it must be operated considering load factors, especially when used outside specified conditions.