Part Number:

HLL05.1F-02M0-G0200-N-11-NNNN-NNNN

Manufacturer: Bosch Rexroth Indramat
Series: HLL Bus Chokes

Current response time:

6 Minutes

35 Seconds

  • MPN: R911398758
  • Rated 4.6 (8 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The Bosch Rexroth Indramat HLL05.1F-02M0-G0200-N-11-NNNN-NNNN is a 2 mH DC bus choke with a nominal current of 200A. It ensures smooth operation with liquid cooling and an 1100V DC bus voltage.

Part Number:

HLL05.1F-02M0-G0200-N-11-NNNN-NNNN

Manufacturer: Bosch Rexroth Indramat
Series: HLL Bus Chokes

Current response time:

3 Minutes

30 Seconds

  • MPN: R911398758
  • Rated 4.6 (8 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The Bosch Rexroth Indramat HLL05.1F-02M0-G0200-N-11-NNNN-NNNN is a 2 mH DC bus choke with a nominal current of 200A. It ensures smooth operation with liquid cooling and an 1100V DC bus voltage.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

For use in industrial automation, the Bosch Rexroth Indramat HLL05.1F-02M0-G0200-N-11-NNNN-NNNN is a high-performance DC bus choke. The choke is known for being reliable, and the HLL line is designed to make power electronics like inverters and converters work better by reducing harmonic distortion and making the system more stable. The choke is specially made for cooling with liquid so that it can keep working well in tough situations.

The HLL05.1F-02M0-G0200-N-11-NNNN-NNNN has a nominal inductance of 2 mH, that makes it perfect for systems with a 200A standard current and a 1100V DC bus voltage. With a temperature range of 40°C, it works well in places where the humidity is less than 90%. The choke has an IP00 rating, that means it doesn't protect against dust or water getting in. This means it can be used in controlled settings. The choke is 55 kg and needs 100 m of space to be installed. The product is made for liquid cooling, that keeps the choke running at its best even when it's under a lot of stress. Bus chokes shouldn't be joined in parallel at both the system's input and output to keep the electricity from going wrong.

As a result of the HLL05.1F-02M0-G0200-N-11-NNNN-NNNN lowering harmonics in DC links, inverters and converters work better, and systems that need high current and voltage levels run smoothly. The choke helps keep the power stable, makes the system work better overall, and lowers electrical noise. This device is most commonly used when people need to store energy, connect to the grid, or generate electricity. For one year, we'll stand for this product, and we ship it all over the world.

HLL05.1F-02M0-G0200-N-11-NNNN-NNNN Technical Specifications

Max Torque: 1.9 Nm
Installation Clearance: 100m
Humidity: Less than 90%
DC Bus Voltage: 1100V DC
Nominal Current: 200A
Product Type: Bus Choke
Cooling Method: Liquid Cooling
Rated Speed: 3000 RPM
Power Supply: 24-48V DC
Nominal Current: 4.3 A
Weight: 2.2 kg
Nominal Inductance: 2 mH
Ambient Temperature: 40°C
Weight: 55 kg
Protection Rating: IP00

Frequently Asked Questions about HLL05.1F-02M0-G0200-N-11-NNNN-NNNN


Q: Why is liquid cooling used in HLL05.1F-02M0-G0200-N-11-NNNN-NNNN?

A: Liquid cooling in the HLL05.1F-02M0-G0200-N-11-NNNN-NNNN ensures efficient heat dissipation during high current operations, improving reliability.

Q: Does HLL05.1F-02M0-G0200-N-11-NNNN-NNNN support high ambient temperatures?

A: The HLL05.1F-02M0-G0200-N-11-NNNN-NNNN supports an ambient temperature of up to 40°C. It ensures stable operation under standard environmental conditions.

Q: How does the nominal inductance of 2mH benefit HLL05.1F-02M0-G0200-N-11-NNNN-NNNN?

A: The 2mH nominal inductance minimizes harmonic distortion. It ensures smooth operation by stabilizing the DC bus voltage and improving power quality.

Q: Why is the IP00 protection rating specified in HLL05.1F-02M0-G0200-N-11-NNNN-NNNN?

A: The IP00 rating means no protection against dust or water ingress. The product is intended for controlled, clean environments, minimizing external contaminants.

Q: Does HLL05.1F-02M0-G0200-N-11-NNNN-NNNN handle high DC bus voltage?

A: Yes, the HLL05.1F-02M0-G0200-N-11-NNNN-NNNN operates at up to 1100V DC. It ensures safe operation in high-voltage systems.

Internal Product Review

  • ‘‘The HLL05.1F-02M0-G0200-N-11-NNNN-NNNN from Bosch is highly reliable for DC bus systems. With a nominal inductance of 2mH and a 200A current capacity, it ensures stable operation under high loads. Its liquid cooling feature and 40°C ambient temperature rating enhance system efficiency and longevity.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo