✓ In-Stock!

Wake Industrial LLC is not an authorized distributor of this product.

SUP-M01-DKCXX.3-040

  • Rated 4.4 (34 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships Today

Current response time:

6 Minutes 12 Seconds

The Bosch Rexroth Indramat SUP-M01-DKCXX.3-040 drive is a part of the DKC Series and features internal fan cooling with a cooling air flow of 150 cubic meters per hour. It supports a control voltage range of 19.2 to 28.8 V DC and a maximum circuit duration power of 12 kW at 480 Volts. The drive also has an insulation resistance of over 25 Megaohms at DC500 V.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The SUP-M01-DKCXX.3-040 from Bosch Rexroth Indramat is a high-performance component in the DKC Series designed to provide maximum power and performance in industrial applications. With a maximum circuit duration power of 10.3 kW at 3 X AC 400 V and 12 kW at 3 X AC 480 V, this unit can support high-demand environments requiring consistent, reliable power. It comes equipped with an internal fan cooling type which has the air flow of 150 m³/h, the SUP-M01-DKCXX.3-040 remains cool and efficient, even when it operates for a long period without rest, thereby lowering the risk of overheating especially when used in extended periods of applications. Its suitability is also found in flexibility by the control voltage range of 19.2 to 28.8 V DC where various operational settings make it fit and integrable to complicated systems.

This Bosch Rexroth model also ensures safety and durability by featuring an insulation resistance of over 25 MOhm at DC500 V, thus offering high protection against electrical shorts and insulation failures. Furthermore, the coupling capacity of 200 nF from the power section to housing stabilizes the unit, reducing interference and ensuring smoother operation. This module can survive at a maximum permissible overvoltage of 45 V for 1 ms (non-repetitive) and withstanding maximum inrush current of 4.0 A. Furthermore, an optimized control current pulse duration of 12 ms and input capacity of 0.9 to 1.2 mF enhance ruggedness in its functionality for industrial use.

The SUP-M01-DKCXX.3-040 is made to work in average conditions and to work well under operating temperature range of +5 to +45 °C with support for operating frequency of 50/60 Hz. It consumes less energy but offers dependable performance through efficient power consumption between 19 and 21 W (device dependent).

SUP-M01-DKCXX.3-040 Technical Specifications

Maximum Circuit Duration Power At 3 X Ac 400 V: 10.3 kW
Control Current Pulse Duration: 12 ms
Input Capacity: 0.9 to 1.2 mF
Power Consumption (device Dependent): 19 - 21 W
Operating Temperature Range: +5 ... +45 °C
Ripple (max): Dependent on input voltage
Operating Frequency: 50/60 Hz
Maximum Circuit Duration Power At 3 X Ac 480 V: 12 kW
Cooling Type: Internal Fan
Cooling Air Flow: 150 m³/h
Insulation Resistance At Dc500 V: > 25 MOhm
Coupling Capacity (power Section To Housing): 200 nF
Control Voltage: (19.2 ... 28.8) V DC
Maximum Permissible Overvoltage: 45 V for 1 ms, non repetitive
Maximum Inrush Current: 4.0 A

Frequently Asked Questions about SUP-M01-DKCXX.3-040


Q: What is the maximum circuit duration power at 3 x AC 400 V for SUP-M01-DKCXX.3-040?

A: The maximum circuit duration power at 3 x AC 400 V for SUP-M01-DKCXX.3-040 is 10.3 kW.

Q: What is the cooling type for SUP-M01-DKCXX.3-040?

A: The SUP-M01-DKCXX.3-040 uses an internal fan for cooling.

Q: What is the operating temperature range of SUP-M01-DKCXX.3-040?

A: The SUP-M01-DKCXX.3-040 operates in a temperature range of +5 to +45 °C.

Q: What is the control voltage requirement for SUP-M01-DKCXX.3-040?

A: The control voltage for the SUP-M01-DKCXX.3-040 is (19.2 ... 28.8) V DC.

Q: What is the maximum inrush current for SUP-M01-DKCXX.3-040?

A: The maximum inrush current for the SUP-M01-DKCXX.3-040 is 4.0 A.

Internal Product Review

  • ‘‘The SUP-M01-DKCXX.3-040 provides reliable performance in industrial applications. Users have noted its consistency and ability to handle demanding tasks with ease. Built with a robust design, it ensures long-term durability, making it a trusted choice for various automation needs. Installation is straightforward, and it performs without complications.’’