Part Number:

DDC01.1-K050B-DC01-01-FW

Manufacturer: Bosch Rexroth Indramat
Series: DDC Series

Current response time:

6 Minutes

36 Seconds

  • Rated 4.6 (19 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The DDC01.1-K050B-DC01-01-FW features a voltage rating of 480V and operates well within a temperature range of -20°C to 60°C. Produced by Bosch Rexroth Indramat as part of the DDC Series, this unit features a protection class of IP55. With an aluminum body, it supports a current rating of 65 A.

Part Number:

DDC01.1-K050B-DC01-01-FW

Manufacturer: Bosch Rexroth Indramat
Series: DDC Series

Current response time:

3 Minutes

40 Seconds

  • Rated 4.6 (19 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The DDC01.1-K050B-DC01-01-FW features a voltage rating of 480V and operates well within a temperature range of -20°C to 60°C. Produced by Bosch Rexroth Indramat as part of the DDC Series, this unit features a protection class of IP55. With an aluminum body, it supports a current rating of 65 A.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The Bosch Rexroth Indramat DDC01.1-K050B-DC01-01-FW is a high-efficiency power unit of the DDC series used in various industrial applications.

This power supply has a voltage of 480V and a current of 65A to support it and is used in providing power to operations that require a lot of energy. The unit works within a temperature bandwidth of -20 degrees Celsius to 60 degrees Celsius allowing it to work in different conditions. It is intended to work at the frequency of 60 Hz; this meets the majority of the industrial standards. This power unit has a small but rather robust casing, with dimensions of 100 x 450 x 250 mm and a weight of 7.5 kg, which makes it possible to install it easily in different systems. The DDC01.1-K050B-DC01-01-FW is made of aluminum alloy, which gives it enough strength and allows it to be light and easy to work with. It is IP55 rated for protection against dust and water, thus suitable for use in challenging conditions. The power lost is only 30W and this is because the energy efficiency is greatly improved. The unit meets EMC Class B requirements, which minimize the unit’s emission of electromagnetic waves and improve its functionality in delicate environments. The control voltage needed is 24V DC which enhances compatibility with other control circuits.

The DDC01.1-K050B-DC01-01-FW has an overloading capability of 200 percent for 60 seconds enhancing power during load surge conditions. The maximum leakage currents are found to be 40 mA, which ensures the safety of the circuit operation. While many other systems use fan-forced cooling, this particular unit relies on convection, which means no fan and is less likely to break down. It can be purchased at Wake Industrial with a one-year warranty.

DDC01.1-K050B-DC01-01-FW Technical Specifications

Voltage Rating: 480 V
Dimensions: 100 x 450 x 250 mm
Weight: 7.5 kg
Control Voltage: 24 V DC
Overload Capacity: 200% for 60 seconds
Rated Leakage Current: 40 mA
Cooling Method: Natural Convection (No Fan Required)
Current Rating: 65 A
Operating Temperature: -20°C to 60°C
Frequency: 60 Hz
Protection Class: IP55
Material: Aluminum
Mounting: DIN rail
Power Loss: 30 W
EMC Level: Class B

Frequently Asked Questions about DDC01.1-K050B-DC01-01-FW


Q: What is the supply voltage range of the DDC01.1-K050B-DC01-01-FW?

A: The DDC01.1-K050B-DC01-01-FW operates at a supply voltage of 480V and supports a current of 65A, making it suitable for high-power industrial operations.

Q: What is the maximum allowable current for the DDC01.1-K050B-DC01-01-FW?

A: The maximum allowable current for this power unit is 65A, ensuring reliable performance for energy-intensive applications.

Q: What is the protection class of the DDC01.1-K050B-DC01-01-FW?

A: The unit has an IP55 protection rating, making it resistant to dust and water, and thus suitable for use in challenging environments.

Q: What temperature range can the DDC01.1-K050B-DC01-01-FW handle?

A: This unit operates efficiently within a temperature range of -20°C to 60°C, ensuring versatility across varying industrial conditions.

Q: Does the DDC01.1-K050B-DC01-01-FW offer overload protection?

A: Yes, the unit can handle up to 200% overload for 60 seconds, providing additional power during surge conditions without compromising safety.