Product Description
The 2AD132C-B05OR2-CS06-C2N1 asynchronous AC motor provided by Bosch Rexroth must be mounted by taking care to ensure that all the specified dimensions and tolerances are maintained. This motor must be worked on only after switching off the power to the machine. The product may cause dangerous drive controller movements because of a fault in its components. This device should be safeguarded against pinching and clamping by using suitable preventive measures. The unit must be handled and mounted by following the general construction and safety guidelines. It can be used only in machinery that is exclusively intended for commercial use.
This motor may tend to get damaged due to improper storage. The product should be stored and transported only in the horizontal orientation. This device uses a blower with airflow guided by the shrouds over its surface. The unit has a fixed output direction for its power connector. It has no support for a foot mounting style. This motor must be used with an ECODRIVE, DIAX04, or INDRADRIVE drive controller. The product portrays an IP 40 protection class for its output shaft. This device must not be operated without a blower. The unit supports digital servo feedback. It comes with a balancing key.
This motor is CE Certified. The product should be assembled, installed, transported, and stored properly for safe and optimum operation. This device has only one temperature sensor connection at a time. The unit tends to depict a high housing temperature if there is a failure of the blower system. Its blower must be dismantled for maintenance only by qualified personnel. This asynchronous motor has increased availability with regular preventive maintenance measures.