Product Description
Indramat Rexroth manufactured the variant 2AD132B-B05OA1-BS03-B2V1 of AC motor. The construction style is flange type, and it comes without holding brakes. Heat accumulates in the motor due to winding and continuous operation. The cooling method to cool down the motor is through an axial blower from B to A. The power consumption of the axial blower is 170 or 145 VA, and the average air volume is 1000 m3/hr. It has a rated speed of 1500 revolutions per minute, and the peak speed with heavy-duty bearings is 7500 revolutions per minute.
The motor 2AD104D-B35OA1-ES06-D2N1 has high-resolution feedback, and the output shaft is balanced with entire key. It doesn't have sealing rings that can be handy in leakages of fluid around the shaft.
The motor 2AD104D-B35OA1-ES06-D2N1 has an NTC thermistor is built into the motor windings. An NTC thermistor is a type of resistor whose resistance decreases as its temperature increases. The NTC thermistor monitor in the drive protects the motor against overheating. The drive sends out an error message if the motor is shut down for thermal reasons. The connection is integrated into the power connection. The ambient temperature of this motor to operate effectively is from 0 C to 45 C.
The 2AD104D-B35OA1-ES06-D2N1 has the average sound pressure level is 75 dB that is tested at a distance of 1 meter, and pulse width modulation of 4 kHz. It has a thermal time constant of 45 minutes which is time to reach approximately 63.2% of its final temperature difference, in case of disturbance. Rexroth recommended regularly cleaning the motor from excessive dust, chips, or similar and checking the function of the surface motor blower.