Product Description
The 2AD100C-B05OA2-AS03/S003 asynchronous motor provided by Bosch Rexroth must have a permanent connection of its housing to the safety conductor at its connection points before turning on its power. This motor encompasses protective caps that have to be removed only just before assembly. The device storage and transportation must take place between -20°C and 80°C. The unit indicates lesser than standard performance when the installation elevation is more than the favorable limit specified. It should be ensured that the motor is free of corrosion and dampness. This motor lifting action must not be accomplished using the blower housing.
The product and/or its components tend to get destroyed due to repeated inspections or improperly executed high-voltage inspection tests. This device is mechanically inspected for concentricity and position tolerances of its shaft end and mounting flange in accordance with DIN 42955 specifications. The unit portrays a 1500m-1 base speed. Its load factors have to be multiplied if both the ambient installation altitude and operating temperature are exceeded. This motor should be free of any throwing, tipping or dropping action when it is being transported. This asynchronous motor features a backup support period valid for one year.
The product must never be connected with accessories or parts that do not have the approval of the manufacturer. This device has a nominal current rating of 27A and a nominal voltage rating of 168V. The unit is intended to be stored in a shock-free place free of dust and dirt. It is necessary to do a replacement of the grease if the storage period is more than five years. This motor warmup has to be done at 1000rpm speed for one hour if the storage duration is between one and five years. The product connection is recommended to be done with the manufacturer’s cables because of their low adhesion properties. This asynchronous motor is shippable to any address irrespective of the country you live in.