✓ In-Stock!

Wake Industrial LLC is not an authorized distributor of this product.

EL6632

  • Rated 4.6 (16 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    Available

Current response time:

5 Minutes 8 Seconds

EL6632 is an EL6xxx series terminal manufactured by Beckhoff. This terminal weighs approx. 75 g, operates at a temperature range of 0 to 55 degrees Celsius, and its current consumption (from the E-bus) is typ. 400 mA.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

Industrial Ethernet networks have been a crucial aspect of the robust and high dynamic industrial floor. However, other networks such PROFIBUS have been developed based on the industrial Ethernet to provide higher speeds, more bandwidth, and support larger messages. To interface a standard Ethernet interface with PROFINET master, a Beckhoff TwinCAT Supplement is used to turn each Beckhoff PC-based control system into a PROFINET IO controller. To widen the PROFINET network to communicate with an EtherCAT network, PROFINET can be coupled with EtherCAT using a Beckhoff PROFINET controller Supplement terminal. Note that the terminal acts as a controller towards PROFINET and as a slave on the EtherCAT end.

The EL6632 is a Beckhoff PROFINET IRT controller that has the capability of offering complete isochronous real-time (IRT) or real-time (RT) functionalities. Easy monitoring and troubleshooting capabilities on the controller are enabled by the onboard status LEDs. When connected in a line topology, the EL6632 can support a maximum of 15 PROFINET RT devices and a maximum of 5 PROFINET IRT devices with the maximum distance between any two devices being 100 meters. For network diagnostics, SNMP or LLDP protocols are used.

The Beckhoff EL6632 supports Windows XP and Windows XP Embedded operating systems and a TwinCAT I/O, CNC, NC I, NC, and PLC software. Target systems for the EL6632 include PC (x86) and Windows CE devices with an EtherCAT interface. The EL6632 has 500 V electrical isolation for the E-bus/Ethernet, a minimum isochronous real-time cycle of 500 microseconds and a minimum real-time cycle of 1 millisecond. The controller’s current consumption is 400 mA via E-bus. For optimal performance, the controller should be operated in a temperature range of 0 to 55 degrees Celsius, stored in a temperature range of -25 to +85 degrees Celsius, and relative humidity should be 95% without condensation.

  • EL-6632
  • el6632

EL6632 Technical Specifications

Current Consumption from E-bus: typ. 400 mA
Conformity class: C
Technology : PROFINET IO
Number of ports/channels: 2
Ethernet Interface: 100BASE-TX Ethernet with 2×RJ 45
Fieldbus: PROFINET RT/IRT controller
Hardware diagnostics : status LEDs
Power supply: via the E-bus
Minumum IRT cycle: 500µs
Drivers: TwinCAT 2.11 R3

Frequently Asked Questions about EL6632


Q: What does the EL6632 do in indusrial control systems?

A: The EL6632 is a PROFINET IO controller that operates as a Twin CAT supplement and turns every Beckhoff PC-based control system into a PROFINET IO Controller. It is very useful in turning an ethernet communication interface to a PROFINET master.

Q: what are the computer operating systems supported by the EL6632 PROFINET IO controller?

A: The EL6632 controller is compatible with PCs that have the Windows XP and XP embedded operating systems. It can be used with up to 5 devices simulteneously.

Q: What do operators need for the proper activation of the EL6632 PROFITNET controller?

A: To ensure that the EL6632 is activated properly, the TwinCAT 2.11 and an Ethernet card in intel chippset is required. The activation should be carried out by an industrial professional according to the instructions in the documentation supplied with the supplement.

Q: Can the EL6632 be used in harsh environmental conditions?

A: The use of the EL6632 in harsh conditions is not permitted. The enclosure of the EL6632 PROFINET controller only provides protection according to IP20. The controller should be installed in another control cabinet that meet at least the IP54 protection before operation.

Q: How can operators detect errors in the EL6632 controller?

A: The EL6632 features several light emmiting diodes that is designed to communicate operational status to operators in real time. In the case of erros, the diodes flash error signals that can be easily interpreted by operators.

Internal Product Review

  • ‘‘The product arrived in perfect condition and was very easy to install. Highly recommended. ’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo