✓ In-Stock!

Wake Industrial LLC is not an authorized distributor of this product.

X20BC1082

  • Rated 4.3 (6 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    Available

Current response time:

3 Minutes 18 Seconds

The X20BC1082 module acts as a hub facilitating connection of I/O nodes to POWERLINK automation systems. It supports up to 2 interface module slots and provides efficient wiring.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

As a key part of decentralized automation architectures, the X20BC1082 module from the X20 series serves to efficiently integrate field-level I/O devices into POWERLINK networks. Functioning as an intelligent hub, it supports connecting up to two remote I/O nodes using X2X Link technology. This offers users a flexible, cost-effective way to distribute input and output points across a machine or process as needed.

Communication is handled exclusively through POWERLINK, the opened standard offering high-speed, real-time data exchange well-suited for demanding motion control and synchronization applications. With configuration and firmware updates remotely managed over this fieldbus, the X20BC1082 streamlines commissioning and maintenance activities. Plant engineers gain simplified, remote access to connected nodes without requiring a PC on location. Tight coordination between nodes is accomplished through 1:1 or POWERLINK-wide cycle synchronization. This precise coordination ensures processes like servo axes move in unison or production line signals toggle in sequence. Integrated intelligence provides distributed intelligence, coordination, and diagnostic abilities comparable to a single centralized PLC system while retaining the advantages of a modular architecture.

Recognizing cost-sensitivity in control cabinets, the X20BC1082 contributes just 2W to power consumption over POWERLINK. Minimal space requirements further enhance appeal for applications with limited shelf space. Weighing in at a mere 155g, multiple modules fit comfortably side-by-side while maintaining ample ventilation for long service life. Rugged designs ready the X20BC1082 for even the most demanding industrial settings. It withstands vibration, shocks, and a wide temperature range per industry standards like CE, UKCA, and ATEX Zone 2. IP20 protection from non-hazardous dust supports periodic cleaning common on plant floors. Global certifications and various approvals provide trustworthy performance anywhere required by machinery directives.

X20BC1082 Technical Specifications

Product Type: Automation module
Authentication: CE, UKCA, ATEX Zone 2
Authentication: CE, UKCA, ATEX Zone 2
communication protocols: POWERLINK
I/O configuration and firmware updates: support via fieldbus
hub integration: provision of efficient wiring
number of slots: up to 2 interface module slots
Function: X2X Link I/O nodes can be connected to POWERLINK
cycle synchronization: 1:1 or POWERLINK
power consumption: bus 2W

Frequently Asked Questions about X20BC1082


Q: How does the X20BC1082 support I/O configuration and firmware updates?

A: The X20BC1082 allows configuration and firmware updates of connected I/O nodes to occur over the fieldbus communication

Q: What is the power consumption of the X20BC1082 module?

A: The power consumption of the X20BC1082 module is 2W when operating on a POWERLINK bus

Q: What authentication standards does the X20BC1082 comply with?

A: The X20BC1082 module is certified to international standards CE, UKCA, and ATEX Zone 2, ensuring appropriate authentication for industrial applications

Q: How many interface module slots are available on the X20BC1082?

A: The X20BC1082 contains up to two interface module slots allowing connection of I/O modules to the POWERLINK network via X2X Link

Q: What types of cycle synchronization are supported?

A: The X20BC1082 facilitates both 1:1 and POWERLINK cycle synchronization between connected I/O nodes and the fieldbus system.

Internal Product Review

  • ‘‘The X20BC1082 is designed for applications requiring POWERLINK connectivity and efficient integration of I/O modules in an automation system. It facilitates wiring and configuration of decentralized X2X Link nodes.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo