Part Number:

X20BB47

Manufacturer: B & R Automation
Series: X20 Fieldbus Input Output Series
  • Rated 4.5 (30 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The B & R Automation X20BB47, part of the X20 Series, features an IP20 protection rating. It incorporates a 1x RS232 connection and a 1x CAN bus connection, with a power consumption of just 0.56 W. The module supports both horizontal and vertical mounting and requires a 24 VDC I/O power supply nominal voltage.

Part Number:

X20BB47

Manufacturer: B & R Automation
Series: X20 Fieldbus Input Output Series
  • Rated 4.5 (30 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The B & R Automation X20BB47, part of the X20 Series, features an IP20 protection rating. It incorporates a 1x RS232 connection and a 1x CAN bus connection, with a power consumption of just 0.56 W. The module supports both horizontal and vertical mounting and requires a 24 VDC I/O power supply nominal voltage.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The X20BB47 is also another bus base module expertly crafted by the renowned automation company, B&R Industrial. It serves as a versatile bus base for the X20 series' Fieldbus CPUs. Like the X20BB37, the X20BB47 provides interfaces for facilitating both the CAN bus and RS232 communication protocols. With this in mind, the X20BB47 also offers a switch for controlling the integrated terminal resistor for the CAN bus. Unlike other bus base modules, this bus base provides two slots for interface modules. The interface modules are the ones responsible for actually initiating and completing communication. The rightmost slot in the X20BB47 is dedicated for the bus controller.

Surprisingly, although the X20BB47 provides an extra interface slot, its nominal power consumption is only 0.56 watts. This estimated power is the total consumption of the bus without any resistive actuators contributing to the power demand. At any point in time, the X20BB47's I/O power supply permits 10 amperes of current contact load and sits with a nominal voltage of 24 VDC. The voltage routing for this bus base module assigns the bottommost route for the ground, while the route above it is for the positive voltage rail at 24 V.

As per EN 60529, the X20BB47's degree of protection class is IP20. Such protection category implies that the bus module prevents accidental contact with objects 12 mm in diameter, for instance, human fingers. The bus module, however, does not offer any resistance to moisture or liquids. To keep it in pristine condition, therefore, the X20BB47 must be properly mounted, stored, and operated in favorable environments with little exposure to small particulates, dust, and liquids. The left and right cover end plates for this bus module come for free upon purchase.

X20BB47 Technical Specifications

Bus Module: X20 fieldbus CPU base, backplane for fieldbus CPU, fieldbus CPU supply module and two interface modules
Operating Conditions, Horizontal Mounting: Yes
Operating Conditions, Vertical Mounting: Yes
Interfaces: 1x RS232 connection, 1x CAN bus connection
Power Consumption, Bus: 0.56 W
Electrical Isolation, Bus - Can Bus: No
Electrical Isolation, Bus - Rs232: No
Ip Protection: IP20
Dnv Gl Certification: Temperature: B (0 - 55 degrees C), Humidity: B (up to 100%), Vibration: B (4 g), EMC: B (Bridge and open deck)
I/o Power Supply Nominal Voltage: 24 VDC
Perm. Contact Load: 10 A

Frequently Asked Questions about X20BB47


Q: What relative humidity is recommended for the X20BB47?

A: During operation, transport, and storage, the recommended humidity for the X20BB47 is between 5 and 95%, non-condensing.

Q: What is the recommended spacing for the X20BB47?

A: The X20BB47 works well with a physical separation distance or spacing of 87.5 millimeters.

Q: Does the X20BB47 provide electrical isolation?

A: Unfortunately, the X20BB47's main bus, CAN bus, and RS232 interfaces are not electrically isolated.

Q: What are the X20BB47's certifications?

A: The X20BB47 adheres to the standards found on these certifications: DNV GL, ATEX, LR, KR, HazLoc, CE, KC, UL, and EAC.

Q: How is the X20BB47 different from the X20BB37?

A: The X20BB47 has two dedicated slots for interface modules whereas the X20BB47 only has one interface. Both, however, support CAN bus and RS232 communication protocols.

Internal Product Review

  • ‘‘The X20BB47 provides several options for establishing communication. With its two interface slots, CAN bus and RS232 communication may be initiated at any time. ’’