Part Number:

8CVI045E1HCS0.00-2

Manufacturer: B & R Automation
Series: 8CVI ACOPOS Inverter Module Series

Current response time:

3 Minutes

44 Seconds

  • Rated 4.4 (34 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The 8CVI045E1HCS0.00-2 ACOPOSremote module features cold plate mounting, DNA support, a 15-pin Tyco connector with a current-carrying capacity of 20 A at 40 degrees C, and a nominal DC bus connection voltage of 750 VDC. Part of the 8CVI Series manufactured by B & R Automation, it is certified for functional safety and has varying power dissipation based on switching frequency.

Part Number:

8CVI045E1HCS0.00-2

Manufacturer: B & R Automation
Series: 8CVI ACOPOS Inverter Module Series

Current response time:

5 Minutes

39 Seconds

  • Rated 4.4 (34 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The 8CVI045E1HCS0.00-2 ACOPOSremote module features cold plate mounting, DNA support, a 15-pin Tyco connector with a current-carrying capacity of 20 A at 40 degrees C, and a nominal DC bus connection voltage of 750 VDC. Part of the 8CVI Series manufactured by B & R Automation, it is certified for functional safety and has varying power dissipation based on switching frequency.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The 8CVI045E1HCS0.00-2 inverter module is a reliable product of B&R. It is a highly durable member of 8CV series, designed to meet the demands of complex industrial environments. Engineered for efficiency, it features a current-carrying capacity of 15-pin TYCO connector with a power contacts of max. 20 A at 40 degrees C. The module also boasts an EnDat 2.1 encoder connection, providing precise feedback essential for sophisticated automation systems. Additionally, it includes DC bus capacitance of 35 uF, a 30 m line length, and electronic fuse protection, making it a safe component for industrial applications.

Motor connection in the 8CVI045E1HCS0.00-2 has two important features including continuous power per motor connection of 1.5 kW and continuous current per motor connection of 4.5 Aeff.

Reduction of continuous current in the8CVI045E1HCS0.00-1 depends on installation elevation, starting at 500 m above sea level. It has the current of 0.45 A per 1,000 m. It also supports Insulation stress of the connected motor per IEC TS 60034-25:2004, having limit value curve if A. The module featured protective measures including, overload protection, short-circuit, and ground fault protection. Moreover, the max. output frequency in this module is 598 Hz.

Status indicators of UP/DN LEDs are also a prominent feature in this inverter unit. This feature is vital in high-demand industrial settings, providing an added layer of protection and ensuring that safety protocols are effectively implemented. Furthermore, the certifications in this unit include CE, UKCA along with functional safety having UL cULus E225616 Power conversion equipment and KC as well., making is a safe unit for the automation industry.

8CVI045E1HCS0.00-2 Technical Specifications

Module Type: ACOPOSremote module
Dc Bus Connection - Power Dissipation Depending On Switching Frequency - Switching Frequency 20 Khz: In preparation
Manufactured : B&R Automation
Weight : 4.8 Kg
Output Voltage: 24 VCD
Continuous Current Per Connection : 1.1 A
Encoder Type : EnDat2.1
Current-carrying Capacity Of 15-pin Tyco Connector - Power Contacts: Max. 20 A at 40 degrees C
Support - Dynamic Node Allocation (dna): Yes
Cooling And Mounting Type: Cold plate mounting
Certifications - Functional Safety: Yes
Dc Bus Connection - Voltage - Nominal: 750 VDC
Dc Bus Connection - Continuous Power Consumption: In preparation
Dc Bus Connection - Power Dissipation Depending On Switching Frequency - Switching Frequency 5 Khz: [0.16 * IM^2 + 5.6 * IM + 55 + (Pout/750)^2 * 0.25] W
Dc Bus Connection - Power Dissipation Depending On Switching Frequency - Switching Frequency 10 Khz: [0.49 * IM^2 + 4.7 * IM + 95 + (Pout/750)^2 * 0.25] W

Frequently Asked Questions about 8CVI045E1HCS0.00-2


Q: What is the nominal voltage of the DC bus connection in the 8CVI045E1HCS0.00-2?

A: The DC bus connection in the 8CVI045E1HCS0.00-2 operates at a nominal voltage of 750 VDC.

Q: Does the 8CVI045E1HCS0.00-2 support flexible system configurations?

A: Yes, the 8CVI045E1HCS0.00-2 supports Dynamic Node Allocation (DNA) for adaptive system configurations.

Q: How does the 8CVI045E1HCS0.00-2 manage thermal dissipation?

A: The 8CVI045E1HCS0.00-2 is designed for cold plate mounting, providing efficient thermal management.

Q: What type of encoder connection does the 8CVI045E1HCS0.00-2 support?

A: The 8CVI045E1HCS0.00-2 features an EnDat 2.1 encoder connection for precise feedback.

Q: What is the current-carrying capacity of the 8CVI045E1HCS0.00-2?

A: The 8CVI045E1HCS0.00-2 by B&R Automation is rated for 20 A at 40 degrees C.

Internal Product Review

  • β€˜β€˜The 8CVI045E1HCS0.00-2 inverter by B&R Automation has a nominal voltage of 750 VDC, ensuring stable power delivery across a wide range of applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo