Part Number:

KL3312-0010

Manufacturer: Beckhoff
Series: KL Analog Input Series
  • Rated 4.4 (33 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The Beckhoff KL3312-0010 is a robust module within the KL Analog Input Series, accommodating two thermocouple sensor inputs. Featuring an IP20 protection rating, it ensures reliable operation. The module consumes 65 mA typical on the K-bus and adheres to EMC standards, with CE, UL, ATEX, IECEx approvals.

Part Number:

KL3312-0010

Manufacturer: Beckhoff
Series: KL Analog Input Series
  • Rated 4.4 (33 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The Beckhoff KL3312-0010 is a robust module within the KL Analog Input Series, accommodating two thermocouple sensor inputs. Featuring an IP20 protection rating, it ensures reliable operation. The module consumes 65 mA typical on the K-bus and adheres to EMC standards, with CE, UL, ATEX, IECEx approvals.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

This KL3312-0010 terminal bus is a versatile two-channel analog input module by Beckhoff designed for precise temperature measurement using thermocouple sensors. Beckhoff company never fails to introduce and design high performance equipment that is found proficient in various industrial automation setups.

This KL3312-0010 terminal bus supports various thermocouple types including J, K, L, B, E, N, R, S, T, and U, with type K set as the default. The device offers a wide measuring range from -100°C to +1370°C for type K sensors and is capable of millivolt measurements in the range of ±30 mV to ±120 mV. With a resolution of 0.1°C per digit. It consists of a conversion time as 250 milliseconds and delivers highly accurate and responsive temperature data. This KL input series device holds 500 V electrical isolation between the K-bus and signal voltage which helps in ensuring safe operation in different environments. It has built-in wiring fail indication and offers less than ±0.5% measurement uncertainty relative to the full scale by making it reliable for critical temperature monitoring tasks. The stripping length for wiring is 8-9 mm with a maximum current load on power contacts of 10 A.

This KL3312-0010 terminal bus thermocouple module weighs just 70 grams and is designed to fit on a standard 35 mm DIN rail mounting category. Its polycarbonate housing provides protection as IP65 while side-by-side mounting is enabled by a double slot and key connection system. The unit operates within a temperature range of 0 to +55°C and complies with multiple industry standards by including CE, UL, ATEX, and IECEx. Its configuration is straightforward as there is no need for address setting with all adjustments made via the Bus Coupler or controller.

KL3312-0010 Technical Specifications

Number Of Inputs: 2
Current Consumption K-bus: typ. 65 mA
Bit Width In Process Image: input: 2 x 16 bit data (2 x 8 bit control/status optional)
Weight: approx. 70 g
Operating/storage Temperature: 0…+55°C/-25…+85°C
Vibration/shock Resistance: conforms to EN 60068-2-6/EN 60068-2-27
Emc Immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4
Power Supply: via the K-bus
Thermocouple Sensor Types: types J, K, L, B, E, N, R, S, T, U (default setting type K), mV measurement
Measuring Range: in the range defined for the sensor (default setting: type K; -100…+1370°C); mV measurement: ±30 mV…±120 mV
Connection Method: 2-wire
Conversion Time: approximately 250 ms
Wiring Fail Indication: yes
Resolution: 0.1°C per digit
Measurement Error/uncertainty: < ±0.5% (relative to full scale value)

Frequently Asked Questions about KL3312-0010


Q: How many thermocouple inputs can the KL3312-0010 handle simultaneously?

A: The KL3312-0010 supports two analog inputs allowing it to handle measurements from two thermocouples at once.

Q: What type of mounting is required for the KL3312-0010?

A: The KL3312-0010 is designed for installation on a 35 mm DIN rail by conforming to EN 60715 with a secure locking mechanism.

Q: How does the KL3312-0010 indicate a wiring failure?

A: The KL3312-0010 includes a built-in wiring fail indication by making troubleshooting easier for technicians.

Q: What are the dimensions of the KL3312-0010?

A: The KL3312-0010 has a compact design with dimensions of 12 mm (W) x 100 mm (H) x 68 mm (D) by saving space in control cabinets.

Q: Can the KL3312-0010 operate in humid environments?

A: Yes, the KL3312-0010 can operate in environments with relative humidity up to 95%, as long as there is no condensation.

Internal Product Review

  • ‘‘The KL3312-0010 of Beckhoff KL analog input series provides precise temperature measurement with 16-bit resolution by making it ideal for industrial applications requiring thermocouple inputs. Its compact design integrates easily into automation systems, and the two-channel capability is a good choice for accurate temperature data collection.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo