✓ In-Stock!

Wake Industrial LLC is not an authorized distributor of this product.

KL3202-0027

  • Rated 4.5 (28 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships 3-5 Days

Current response time:

5 Minutes 2 Seconds

The KL3202-0027, from the Beckhoff KL Analog Input Series, features two inputs powered via the K-bus. It offers a 16-bit resolution and a conversion time of approximately 250 ms. The device weighs about 70 grams and conforms to IP20 protection standards with a vibration resistance as per EN 60068-2-6.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

This component KL3202-0027 by Beckhoff is a high-performance analog input terminal bus designed for temperature measurement with resistance sensors by offering exceptional versatility for PLC modules. It is a product of Beckhoff which is a high-grade company that manufactures components for industrial automation technology.

This KL3202-0027 terminal bus module works with both 2-wire and 3-wire connection methods with a default 3-wire configuration. This device is compatible with a various sensor type as including Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000 and resistance measurement sensors like potentiometers. The measuring range extends from -200°C to +850°C for Pt sensors and -60°C to +250°C for Ni sensors by providing precise temperature monitoring for various industrial applications. It functions with a conversion time of approximately 250 milliseconds and a measurement resolution of 0.1°C per digit. This KL analog input series device delivers fast and highly accurate readings. The system is designed with open-circuit recognition and can detect sensor faults such as broken wires. Its microprocessor-controlled linearization ensures accuracy over the entire temperature range while the typical measurement uncertainty remains below ±1°C.

The KL3202-0027 terminal bus operates efficiently on a K-bus power supply by consuming around 60 mA of current without the need for power contacts. It has 500V electrical isolation between the K-bus and signal voltage by ensuring safety and reliability in demanding environments. Its construction meets the proper standards for vibration and shock resistance with a protection rating of IP20. Also, it is designed for installation on a 35 mm DIN rail mounting and is certified with CE, UL, and ATEX/IECEx approvals. Its compact form factor and spring wiring make it easy to install and maintain by ensuring long-term durability in many useful tasks related to PLC designs.

KL3202-0027 Technical Specifications

Number Of Inputs: 2
Weight: approx. 70 g
Operating/storage Temperature: -25…+60°C/-40…+85°C
Vibration/shock Resistance: conforms to EN 60068-2-6/EN 60068-2-27
Emc Immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4
Protection Rating/installation Pos.: IP20/variable
Approvals/markings: CE, UL, ATEX, IECEx, DNV GL
Power Supply: via the K-bus
Sensor Types: RTD (10…10 kΩ)
Resolution: 16 bit
Conversion Time: ~ 250 ms
Measuring Current: typ. 0.5 mA
Measurement Error: < ±1°C
Current Consumption K-bus: typ. 60 mA
Bit Width In The Process Image: input: 2 x 16 bit data (2 x 8 bit control/status optional)

Frequently Asked Questions about KL3202-0027


Q: How is the KL3202-0027 powered?

A: The KL3202-0027 is powered via the K-bus consuming approximately 60 mA. This eliminates the need for additional power contacts and simplifies installation.

Q: How does the KL3202-0027 detect sensor faults?

A: The KL3202-0027 features open-circuit recognition and error LEDs that indicate sensor faults such as broken wires. This ensures timely detection and correction of sensor issues.

Q: What is the measuring range for Pt and Ni sensors on the KL3202-0027?

A: The KL3202-0027 measures temperatures between -200°C and +850°C for Pt sensors and -60°C to +250°C for Ni sensors. This wide range accommodates various industrial temperature applications.

Q: What is the default connection method for the KL3202-0027?

A: The KL3202-0027 operates with both 2-wire and 3-wire configurations, but the default setting is a 3-wire connection. This ensures accurate and stable temperature readings.

Q: What is the maximum current load for the KL3202-0027’s power contacts?

A: The KL3202-0027’s power contacts can handle a maximum current of 10 A ensuring reliable power distribution within the system.

Internal Product Review

  • ‘‘The KL3202 by KL input analog series of Beckhoff is a highly reliable and efficient analog input terminal for resistance sensors. Its 2-wire and 3-wire connection flexibility, along with microprocessor-controlled linearization and built-in error LEDs provide instant fault detection for temperature monitoring. ’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo