The Beckhoff KL3202-0021 is a part of the KL Analog Input Series and features a sensor compatibility with Pt100 and Ni100 models. It supports a measuring range from -200 to +850°C for Pt sensors and -60 to +250°C for Ni sensors. It includes open-circuit recognition and operates efficiently with a power supply via the K-bus.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The product of Beckhoff as KL3202-0021 is a highly versatile analog 2 channel input bus terminal which is designed for proper temperature readings in industrial automation applications. Beckhoff company mainly offers products as controllers, software, and I/O systems to help machines to process tasks efficiently by improving performance and productivity in various sectors.

This KL3202-0021 terminal bus contains a wide range of resistance temperature detectors (RTDs) such as Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, and Ni1000 sensors. Its capability to handle different sensor types makes it suitable for diverse temperature monitoring needs. It even covers a measuring range of -200°C to +850°C for Pt sensors and -60°C to +250°C for Ni sensors. This KL input series terminal bus compact structure is designed for I/O systems with power supplied via the K-bus and no additional power contacts required. The terminal operates with a typical measuring current of 0.5 mA and delivers a resolution of 0.1°C per digit. This feature helps in ensuring highly accurate readings. The conversion time is approximately 250 ms which strikes a good balance between speed and precision for most industrial processes. It offers an uncertainty of less than ±1°C by making it a reliable option for sensitive temperature reading.

This KL3202-0021 terminal bus features out another key aspect as its open-circuit recognition which helps ensure consistent performance and decreases chance of error while working. It also meets high safety and quality standards, with electrical isolation up to 500 V and compliance with international regulations such as CE, UL, ATEX, and IECEx certifications. Its IP20-rated polycarbonate housing, compact design, and vibration resistance make it suitable for toxic industrial environments and its compatibility with a wide variety of wiring setups simplifies installation.

KL3202-0021 Technical Specifications

Number Of Inputs: 2
Current Consumption K-bus: typ. 60 mA
Bit Width In The Process Image: input: 2 x 16 bit data (2 x 8 bit control/status optional)
Special Features: open-circuit recognition
Operating/storage Temperature: -25…+60°C/-40…+85°C
Vibration/shock Resistance: conforms to EN 60068-2-6/EN 60068-2-27
Power Supply: via the K-bus
Sensor Types: Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement
Measuring Range: -200…+850°C (Pt sensors); -60…+250°C (Ni sensors)
Connection Method: 2- or 3-wire (default: 3-wire)
Conversion Time: ~ 250 ms
Measuring Current: typ. 0.5 mA
Resolution: 0.1°C per digit
Measurement Error/uncertainty: < ±1°C

Frequently Asked Questions about KL3202-0021


Q: Can the KL3202-0021 recognize sensor open-circuit conditions?

A: KL3202-0021 features open-circuit recognition, which helps in detecting issues such as disconnected or faulty sensors.

Q: Does the KL3202-0021 require an external power supply?

A: No, the KL3202-0021 is powered via the K-bus by eliminating the need for an external power supply to operate the terminal.

Q: What kind of wiring is supported by the KL3202-0021?

A: The KL3202-0021 supports 2-wire or 3-wire connections, with 3-wire being the default option by providing flexibility for different wiring setups.

Q: What are the humidity tolerance levels for the KL3202-0021?

A: The KL3202-0021 can withstand up to 95% relative humidity without condensation, making it good for use in various industrial settings.

Q: What is the typical measuring current used by the KL3202-0021?

A: The KL3202-0021 operates with a typical measuring current of 0.5 mA, which is optimized for accurate RTD sensor readings .

Internal Product Review

  • ‘‘The Beckhoff KL3202-0021 from KL analog input series excels in industries by offering high-precision temperature monitoring with its high resolution. Its dual-channel support and Pt100 compatibility make it a reliable choice for various RTD-based applications by ensuring seamless integration with Beckhoff’s modular I/O systems.’’