In-Stock, Ships 3-5 Days
Part Number:

KL2408-0018

Manufacturer: Beckhoff
Series: KL Analog Input Series

Current response time:

5 Minutes

4 Seconds

  • Rated 4.5 (25 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The KL2408-0018 module from Beckhoff's KL Analog Input Series boasts an output current of 0.5 A per channel, 8 outputs with short-circuit protection, and a nominal voltage of 24 V DC. The series, manufactured by Beckhoff, includes reverse voltage protection and vibration resistance in compliance with EN 60068-2-6 standards.

In-Stock, Ships 3-5 Days
Part Number:

KL2408-0018

Manufacturer: Beckhoff
Series: KL Analog Input Series

Current response time:

5 Minutes

53 Seconds

  • Rated 4.5 (25 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The KL2408-0018 module from Beckhoff's KL Analog Input Series boasts an output current of 0.5 A per channel, 8 outputs with short-circuit protection, and a nominal voltage of 24 V DC. The series, manufactured by Beckhoff, includes reverse voltage protection and vibration resistance in compliance with EN 60068-2-6 standards.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The KL2408-0018 from Beckhoff is an 8-channel digital output terminal that can be used to send binary data to actuators and control them. Beckhoff is known for making high-performance automation tools that can be used in a wide range of industrial settings. The digital output terminal has reliable output switching and electrical isolation to ensure safe and effective activities.

The KL2408-0018 digital output terminal has eight positive-switching digital outlets, and each works at a voltage of 24 V DC. The output terminal works with a 1-wire link technology that makes wiring in control systems easier. It protects against short circuits with a maximum current of less than 2 A and against wire mistakes by preventing reverse polarity. The terminal can break each output channel with less than 150 mJ of energy. Together with the load, the terminal uses about 60 mA of current on the power contacts and 18 mA on the K-bus. With dimensions of 12 mm (W) x 100 mm (H) x 68 mm (D), the KL2408-0018 is small enough to fit in places where room is limited.

The environmental specs of the KL2408-0018 ensure that it will work reliably in temperatures from -25°C to +60°C and up to 95% relative humidity without condensation. The terminal meets IP20 standards for protection, which means it can handle solid items but not water. The terminal has been cleared by UL, CE, IECEx, ATEX, DNV GL, and cFMus, so it can be used in a number of controlled areas. Wake Industrial will replace the digital output terminal if it breaks within a year, and we ship all over the world to meet your industrial automation needs.

KL2408-0018 Technical Specifications

Connection Technology: 1-wire
Current Consumption K-bus: typ. 18 mA
Bit Width In The Process Image: 8 outputs
Weight: approx. 70 g
Operating/storage Temperature: -25…+60°C/-40…+85°C
Vibration/shock Resistance: conforms to EN 60068-2-6/EN 60068-2-27
Emc Immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4
Number Of Outputs: 8
Nominal Voltage: 24 V DC (-15%/+20%)
Load Type: ohmic, inductive, lamp load
Output Current: 0.5 A (short-circuit proof) per channel
Short-circuit Current: < 2 A
Breaking Energy: < 150 mJ/channel
Reverse Voltage Protection: yes
Current Consumption Power Contacts: typ. 60 mA + load

Frequently Asked Questions about KL2408-0018


Q: How does the KL2408-0018 manage short-circuit currents?

A: The KL2408-0018 limits short-circuit current to under 2 A. This feature protects connected devices from potential overcurrent damage.

Q: Why do KL2408-0018 outputs switch positively?

A: The positive switching outputs allow for efficient control of actuators. It ensures reliable performance in various automation systems.

Q: Does the KL2408-0018 support hazardous area approvals?

A: Yes, the KL2408-0018 is approved by ATEX and IECEx. It is suitable for use in environments requiring these certifications.

Q: Do KL2408-0018 power contacts consume high current?

A: The power contacts of the KL2408-0018 consume approximately 60 mA plus load. This ensures optimized energy efficiency in operations.

Q: Why does the KL2408-0018 use 1-wire technology?

A: The 1-wire connection simplifies wiring and installation. It allows for easier integration into industrial control systems.

Internal Product Review

  • ‘‘The Beckhoff KL2408-0018 offers eight positive-switching outputs with 1-wire connection technology. It provides short-circuit protection under 2 A, making it reliable for actuator control. With its compact 12 mm width and operating temperature range of -25°C to +60°C, this terminal is ideal for space-saving installations.’’