In-Stock, Ships Fast
Part Number:

IE3312-0000

Manufacturer: Beckhoff
Series: IE Extension Box Series

Current response time:

3 Minutes

48 Seconds

  • Rated 4.6 (28 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The IE3312-0000 features four inputs and utilizes an M12 socket for thermocouple connections. Designed by Beckhoff, this component is part of the IE Extension Box Series and is suitable for various sensor types, with a default type K measuring range of -100 to +1370°C. It provides an IP65/66/67 protection rating.

In-Stock, Ships Fast
Part Number:

IE3312-0000

Manufacturer: Beckhoff
Series: IE Extension Box Series

Current response time:

5 Minutes

53 Seconds

  • Rated 4.6 (28 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The IE3312-0000 features four inputs and utilizes an M12 socket for thermocouple connections. Designed by Beckhoff, this component is part of the IE Extension Box Series and is suitable for various sensor types, with a default type K measuring range of -100 to +1370°C. It provides an IP65/66/67 protection rating.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The Beckhoff IE3312-0000 fills the role of an analog input module from the IE Extension Box Series and is intended only for the temperature measurement of the thermocouples in a more careful way. It has four such inputs and in addition it can be functional to J, K, L, B, E, N, R, S, T, U thermocouples thermal as well as mV sensing. With a permission for further development, this module is in the standard configuration for Type K thermocouples which can measure from -100 ° C to +1370 ° C. It can produce very precise measurements within a range of 0.1 ° C as the digit per resolution and a less than ±0.5% per full scale value for the uncertainty of the measuring.

Nominal value and tolerance value of this voltage with load is 24 V DC and from -15% to +20%. This module allows you to thermocouples mounted M12 connectors 2-wire method which is proficiently secure. The conversion time is also adjustable though it covers a wide range of effectiveness with the maximum adjustment time of 250 ms and the minimum of 70ms. To improve signal processing, the module contains five configurable input filters.

An M8 male socket is the primary power supply input while an M8 female socket allows a downstream connection for easy daisy chain in extending setups. The module has a very low power consumption of 40 mA (without taking the sensor current into account) therefore it’s economical. An M8 male sockets is the male power supply input and adds Connectable end M8 female socket arrangements that helps in closure easy extensions.

IE3312-0000 Technical Specifications

Number Of Inputs: 4
Current Consumption From Us (without Sensor Current): 40 mA
Power Supply Connection: feed: 1 x M8 male socket, 4-pin, a-coded; downstream connection: 1 x M8 female socket, 4-pin, a-coded
Bit Width In The Process Image: input: 4 x 16 bit data (4 x 8 bit control/status optional)
Operating/storage Temperature: 0…+55°C/-25…+85°C
Vibration/shock Resistance: conforms to EN 60068-2-6/EN 60068-2-27
Emc Immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4
Connection Method: M12 socket, 2-wire connection for thermocouple
Sensor Types: types J, K, L, B, E, N, R, S, T, U (default setting type K), mV measurement
Measuring Range: depending on sensor type; preset value is type K, -100…+1370°C
Resolution: 0.1°C per digit
Measurement Error/uncertainty: < ±0.5% (relative to full scale value)
Conversion Time: approx. 250 ms, configurable up to 70 ms
Nominal Voltage: 24 V DC (-15%/+20%)
Input Filter: 5 variations, configurable

Frequently Asked Questions about IE3312-0000


Q: How many inputs does this device have?

A: The device has 4 inputs.

Q: What type of connection method is used for the thermocouples?

A: The connection method is via an M12 socket with a 2-wire connection for thermocouples.

Q: What sensor types are supported by this device?

A: The device supports sensor types J, K, L, B, E, N, R, S, T, U (with the default setting for type K) and mV measurement.

Q: What is the measuring range for the sensors?

A: The measuring range depends on the sensor type, with the preset value for type K ranging from -100 to +1370°C.

Q: What is the resolution, measurement error, and conversion time for this device?

A: The resolution is 0.1°C per digit, the measurement error/uncertainty is less than ±0.5% (relative to the full scale value), and the conversion time is approximately 250 ms, configurable up to 70 ms.

Internal Product Review

  • ‘‘The Beckhoff IE3312-0000, part of the IE Extension Box Series, can read numerous sensor types, including J, K, and N, with a precision of 0.1°C each digit. It has a measurement range of -100 to +1370°C and runs on a nominal voltage of 24 V DC. The protection level is IP65/66/67.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo