Part Number:

EL9410

Manufacturer: Beckhoff
Series: EL EtherCAT Terminal Series
  • Rated 4.3 (38 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The EL9410 features an input voltage of 24 V DC with a tolerance of -15% to +20%, an output current of 2 A, and a short-circuit proof design while conforming to EN 61000-6-2/EN 61000-6-4 standards. As part of the EL EtherCAT Terminal Series manufactured by Beckhoff, it provides diagnostics in the process image and weighs approximately 65 grams.

Part Number:

EL9410

Manufacturer: Beckhoff
Series: EL EtherCAT Terminal Series
  • Rated 4.3 (38 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • Call for Expedited Shipping and Product Condition Options
Free Ground Shipping
Worldwide Delivery
Repair Options Available

The EL9410 features an input voltage of 24 V DC with a tolerance of -15% to +20%, an output current of 2 A, and a short-circuit proof design while conforming to EN 61000-6-2/EN 61000-6-4 standards. As part of the EL EtherCAT Terminal Series manufactured by Beckhoff, it provides diagnostics in the process image and weighs approximately 65 grams.

Preparing your secure checkout page...

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

A strong and adaptable part made for industrial automation applications is the EL9410, produced by Beckhoff Automation. It provides dependable power distribution and diagnostic capabilities, and as a part of the EL EtherCAT Terminal family, it connects into EtherCAT networks with ease. The EL9410's capacity to provide a steady 24 V DC power source with a 2 A output current is one of its key characteristics. With a tolerance of 15% to 20%, this voltage range guarantees compatibility with a wide variety of industrial equipment. Because it can provide up to 2 A of current, it can power many actuators, sensors, and other automation system peripherals. In addition, the EL9410 has a 5 V output that is intended to power the EtherCAT system's communication backbone, the E-bus. Stable and dependable communication between the EtherCAT master and the linked terminals is guaranteed by this dedicated power supply.

An essential safety element in industrial settings where unforeseen electrical failures may occur is the EL9410's short-circuit-proof construction. In the case of a short circuit, this protective mechanism keeps the terminal and any connected devices safe. The EL9410 further demonstrates its compliance with electromagnetic compatibility (EMC) criteria by adhering to the EN 61000-6-2/EN 61000-6-4 standards. This guarantees that the terminal is safe from outside electromagnetic disturbances and runs dependably without interfering with other electronic devices.

Real-time problem identification and monitoring are made possible by the EL9410's direct integration of diagnostics capabilities into the process picture. By giving instant feedback on the terminal's operational state, this function facilitates preventive maintenance and minimizes downtime. The EL9410 is a lightweight and small device that weighs around 65 grams, making it appropriate for applications with limited space. Its working temperature range of 0°C to +55°C guarantees dependable operation in a variety of industrial settings. Wake Industrial gives its clients peace of mind and guarantees the EL9410's quality and dependability with a one-year warranty.

EL9410 Technical Specifications

Short-circuit Proof: yes
Weight: approx. 65 g
Operating/storage Temperature: 0…+55°C/-25…+85°C
Emc Immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4
Input Voltage: 24 V DC (-15%/+20%)
Input Current: typ. 70 mA + (E-bus/4)
Output Voltage: 5 V for E-bus supply
Output Current: 2 A
Current Consumption E-bus: -
Power Contacts: max. 24 V DC/max. 10 A
Diagnostics In The Process Image: yes
Special Features: standard EL supply

Frequently Asked Questions about EL9410


Q: What is the primary function of the Beckhoff EL9410?

A: The Beckhoff EL9410 is an EtherCAT terminal that primarily provides a stable 24 V DC power supply with an output current of 2 A for industrial automation applications. Designed to integrate seamlessly into EtherCAT networks, it ensures reliable power distribution and supports diagnostics in the process image, allowing for real-time monitoring.

Q: What voltage and current specifications does the EL9410 have?

A: The EL9410 operates with an input voltage of 24 V DC with a tolerance of -15% to +20% and provides an output current of 2 A. It also includes a dedicated 5 V output for powering the E-bus, which is essential for maintaining stable communication within the EtherCAT network. This range ensures compatibility with a variety of industrial devices, including sensors and actuators commonly used in automation.

Q: Does the EL9410 conform to any standards for electromagnetic compatibility?

A: Yes, the EL9410 conforms to the EN 61000-6-2 and EN 61000-6-4 standards for electromagnetic compatibility (EMC). These standards ensure that the terminal can operate without causing interference to other electronic equipment and is protected from external electromagnetic disturbances, making it a reliable choice for industrial environments where such disturbances are common.

Q: What safety features does the EL9410 have?

A: The EL9410 is designed with a short-circuit-proof feature, which is crucial for preventing damage to the terminal and connected devices in case of a short circuit. This protection ensures operational safety in industrial settings, where unexpected electrical faults may occur. Additionally, its robust design allows it to support continuous operation in challenging environments, adding to its reliability.

Q: How does the EL9410 support diagnostics?

A: Diagnostics for the EL9410 are integrated directly into the process image, allowing for real-time fault detection and monitoring. This capability enables proactive maintenance, helping users identify issues early and minimize system downtime. With this feature, the EL9410 provides immediate feedback on its operating status, which is particularly useful for industrial applications requiring continuous monitoring and high reliability.

Internal Product Review

  • ‘‘The EL9410 offers reliable power distribution within an EtherCAT system. The unit supports 24 V DC power contacts up to 10 A and includes integrated diagnostics for easy troubleshooting. Compact and lightweight, the EL9410 is suitable for various industrial applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo